NON-PARTIAL DISCHARGE POWER-FREQUENCY TESTING TRANSFORMERS
    NON-PARTIAL DISCHARGE POWER-FREQUENCY TESTING TRANSFORMERS

Product Description:

NON-PARTIAL DISCHARGE POWER-FREQUENCY TESTING TRANSFORMERS    

Usage:

It is used for checking the insulation level of power-frequency voltage of all kinds of insulation materials and electric products, ParTial discharge level It is frequently needed in electric manufacturers, power companies, scientific research institutes and universities. 

Performance:

The 50-1800kV non-partial, discharge power-frequency testing transformers have passed the appraisal of two-ministries. The soilage transformer has obtained the national practical patent. The factory is the unique one to manufacture the sustaining transformer. They are mostly used in Sino-foreign joint venture power transformer manufacturers (shanghai- Areva for example). Main technique capabilities are domestic-leading and keep ahead in the world. 

Characteristics:  

1ã€Packaged equipment’s can be easily combined. There are adequate series of voltage capacity, and the capability of them is powerful. 
2
ã€Non-partial discharge epoxy insulation pail is successfully invented. It could reduce the partial discharge charge, and it can keep ahead inland. 
3
ã€High quality DQ1 30-30 magnetic particle-directing silicon sheet and 45ompletely mitered sheet are used. Change rate of the wave of products and non-load current is the smallest inland. 
4
ã€Impedance voltage is lower than the determination of the national standard. 
5
ã€Auto-control technique and computer (optical fiber) controlling technique are used. Highly automatic technique results in the strong noise-proof feature. 
6
ã€The reliable fast-electron protecting ins tuitions is used. 


Main Technical Parameters: 

ModelRated Capacity(KVA)High Voltage(KV)Low Voltage(KV)OD*height(mm)Weight (kg)
 YMTCW-5/2×5051000.22/0.38Φ415×95083
  YMTCW-10/2×8081600.22/0.38Φ470×1100120
  YMTCW-20/2×100202000.22/0.38 Î¦850×1950700
  YMTCW-100/2×1001002000.22/0.38  Î¦1250×19502100
  YMTCW-50/2×125502500.38/0.6  Î¦1450×24001400
  YMTCW-250/2×1252502500.22/0.38  Î¦1800×25003300
  YMTCW-150/2×1501503000.38/6  Î¦1800×32003600
  YMTCW-300/2×1503003000.6/3  Î¦1800×32005100
  YMTCW-200/2×2002004000.38/6  Î¦1800×37003800
  YMTCW-400/2×2004004000.6/3  Î¦2000×38004500
  YMTCW-250/2×2502505000.6/3  Î¦2750×51005600
  YMTCW-500/2×2505005000.6/3  Î¦2750×51007800
  YMTCW-1000/2×25010005000.6/3  Î¦2750×51009800
  YMTCW-300/2×3003006000.6/3  Î¦2750×55008000
  YMTCW-600/2×3006006003/6/10.  Î¦2725×567011000
  YMTCW-200/2×30012006003/6/10.  Î¦3000×567017000
  YMTCW-375/2×3753757500.6/3  Î¦2870×630014000
  YMTCW-750/2×3757507503/6/10.  Î¦3000×650017000
  YMTCW-1500/2×37515007503/6/10.  Î¦3000×650020000
  YMTCW-400/2×4004008000.6/3/10  Î¦3200×750015000
  YMTCW-800/2×4008008003/6/10.  Î¦3200×760024000
  YMTCW-1600/2×40016008003/6/10.  Î¦3200×760029000
  YMTCW-500/2×50050010000.6/3/6  Î¦3200×900022000
  YMTCW-1000/2×500100010003/6/10.  Î¦3700×910030000
  YMTCW-2000/2×500200020003/6/10.  Î¦3700×910042000
  YMTCW-4000/2×500400010006/10.  Î¦4000×920062000
  YMTCW-550/2×55055011003/6.  Î¦4000×960024000
  YMTCW-1100/2×550110011003/6/10.  Î¦4000×1060032000
  YMTCW-2200/2×550220011003/6/10.  Î¦4000×1000044000
  YMTCW-1200/2×600120012003/6/10.  Î¦4300×1200050000
  YMTCW-2400/2×600240012003/6/10.  Î¦5400×1460056000
  YMTCW-4800/2×600480012003/6/10.  Î¦5400×1070061000
  YMTCW-1200/3×400120012003/6/10.  Î¦5000×1 100052000
  YMTCW-1500/3×500150015003/6/10.  Î¦5000×1480058000
  YMTCW-3000/3×500300015003/6/10.  Î¦5400×1480064000
  YMTCW-1650/3×550165016506/10.  Î¦5400×1600066000
  YMTCW-3600/3×6003600180010  Î¦5500×1700078000
  YMTCW-6400/3×6003600180010  Î¦5600×1700098000